The four-chute workhorse of the JIACUI A-series. Twice the chutes of the CS-2A128, a 780 kg frame and 3.2 kW of installed power, built for coffee, beans and pulses at 3–5.5 t/h.
CS-4A is the volume step after the CS-2A128. Four chutes and 256 channels take nominal capacity to 3–5.5 t/h while keeping one compact frame — 1940 × 1490 × 1690 mm — and a 3.2 kW drive. It is the model most often specified for coffee and pulse plants that run two or three shifts.
Because it covers coffee, beans and pulses, CS-4A is ordered both as a coffee machine and as a multi-purpose bean line. The bean-specific configuration, changeover routine and sample-test policy are set out on the dedicated bean CS-4A page.
Its general-purpose carryover is >10:1. For premium coffee, where every good bean counts, the higher >120:1 ratio of the two-chute CS-2A128 may matter more than raw throughput.
Coffee, beans and pulses share one platform. Recipes are stored per material, so switching between green coffee, roasted coffee and a bean lot is a changeover, not a new machine.
| Model | Channels | Type | Capacity (t/h) | Power (kW) | Weight (kg) | Accuracy | Carryover | Typical application |
|---|---|---|---|---|---|---|---|---|
| CS-4A | 256 | Chute | 3 – 5.5 | 3.2 | 780 | ≥99.99% | >10:1 | Coffee, beans, pulses |
Frame dimensions: 1940 × 1490 × 1690 mm (L × W × H). Capacity is nominal and changes with material, grade, moisture and the carryover required. Power supply is built to the destination voltage.
Two questions decide the choice: the peak tonnage you must cover, and whether one machine has to handle coffee and pulses as well.
| Model | Channels | Type | Capacity (t/h) | Power (kW) | Weight (kg) | Carryover | Best for |
|---|---|---|---|---|---|---|---|
| CS-2A128 | 128 | Chute | 1.2 – 2.5 | 1.8 | 290 | >120:1 | Specialty coffee, export preparation |
| CS-4A | 256 | Chute | 3 – 5.5 | 3.2 | 780 | >10:1 | Volume coffee, beans and pulses |
| CS-5A | 320 | Chute | 4 – 8 | 4.0 | 920 | >10:1 | Coffee, salt, beans — higher tonnage |
| CS-6A | 384 | Chute | 5 – 9 | 5.6 | 1060 | >10:1 | Rice and high-tonnage lines |
CS-4A is the right size for most coffee and pulse plants. Choose CS-5A when peak demand regularly exceeds 5.5 t/h, or CS-2A128 when the lot value is high and carryover matters more than tonnage.
Custom frame heights, RAL machine colour, OEM branding and destination-voltage builds are handled through our custom color sorter service.
Rice is the primary duty, but the platform is set up for the whole mill flow: paddy before husking, milled white rice after polishing, parboiled rice on a separate recipe, and by-grades such as long, round, half and broken rice. Each stage is stored as its own recipe, so the operator switches product without re-teaching the machine. The same chute also handles sesame, pulses and small grains when the mill runs seasonal campaigns.
This tier is for a mill or plant that already runs a continuous line and needs headroom for peak intake. It holds two or three chutes worth of stream and leaves room for a re-run of the reject fraction without stopping the main flow. The limiting factor moves from the sorter to the feed conveyor and the outfeed bins. The installed figures are 3-5.5 t/h, 3.2 kW and 780 kg in a 1940 x 1490 x 1690 mm frame. 256 channels means 256 independently switched ejectors, so a defect only costs the air of the nozzle that fires.
Two site details decide whether the machine performs as specified: a steady, single-layer feed and a clean, dry air supply. A feed that arrives in surges forces the operator to slow the belt or chute, which gives away tonnage that the machine is capable of holding.
At the top of the 3-5.5 t/h range, an eight-hour shift is 44 tonnes of feed. Running at a realistic 85% utilisation for changeovers, cleaning and grade switches, plan on about 37.4 tonnes per shift. That is the number to compare with your intake, not the peak figure on the specification sheet.
Reject volume is set by your defect load, not by the machine. At a 2% reject rate the sorter removes roughly 110 kg per hour at full rate, and every kilogram of reject carries good product with it. The stated carryover means that for every 10 rejected particles about one good particle goes with them, or about 9.1% of the reject stream by count. On a high-value product that percentage is the number that decides payback, which is why we quote carryover beside capacity rather than in a footnote.
Energy is the smaller cost line. At 3.2 kW installed, the machine draws about 0.58 kWh per tonne at full rate, and roughly 6144 kWh over 300 eight-hour days at 80% load. Compressed air, belt and nozzle wear, and the labour needed to clean the inspection window usually cost more than the electricity, so the maintenance plan in the next section matters more than the motor rating.
The machine arrives as one transport unit and is positioned on a level concrete floor with access to both sides for cleaning and service. Allow for a feed conveyor or hopper at the inlet and two outfeed bins at the outlet; the reject bin must be easy to empty because it fills fastest on a dirty lot. Lifting points are marked on the frame, and the frame weight is 780 kg, so plan lifting gear and a clear path before delivery rather than after it.
Services are a compressed-air drop at 0.6-0.8 MPa with dry, oil-free air, and a power supply built to the destination voltage and frequency. Commissioning covers mechanical alignment, belt tracking where a belt is fitted, air-pressure setting, a camera calibration on a reference card and a first recipe run on your own material. We ask for 5-10 kg of representative feed in advance so the first recipe is close before the engineer arrives.
A two- to four-hour run with your operator present is part of commissioning: the recipes are tuned to your grades, the operator is trained on the touchscreen and the reject-rate target is agreed before sign-off. Remote support stays connected after commissioning for recipe adjustments as your incoming lots change.
The wear list is short and known. Ejector nozzles, filters on the air line, the inspection window and the lighting module are the parts that need routine attention; on a belt machine the belt itself and its cleaning scraper are added to the list. Nozzles are replaced individually, not as a block, so a failed ejector is a low-cost item rather than a reason to stop the line.
Daily work is cleaning: wipe the inspection window, check the air pressure, empty the reject bin and look at the feed for surges. Weekly work adds a nozzle test from the touchscreen, a check of the camera image against the reference card and a belt-tracking check on belt models. Annual work is the full calibration and a leakage verification on X-ray machines for the HACCP file.
Keep a small spares kit on site: a set of nozzles, an air filter element, a window and an LED module. That kit covers almost every unplanned stop, and the remote support connection lets our engineers read the machine log before a technician is dispatched, so a minor fault does not turn into a week of downtime.
Choose CS-4A when peak demand is above about 2.5 t/h, or when one machine must cover coffee alongside beans and pulses. Choose CS-2A128 when volumes are smaller and the higher >120:1 carryover protects expensive green coffee.
CS-5A adds one more chute and 64 more channels, taking nominal capacity to 4–8 t/h at 4.0 kW and 920 kg. If your normal peak fits inside 3–5.5 t/h, CS-4A is the more economical unit; if peak demand regularly passes 5.5 t/h, size up to CS-5A.
Chute-type machines handle beans well when the feed rate and chute angle are set for the lot. We measure breakage on your own sample during the free test and report the figure before you order.
3–5.5 t/h is nominal for the platform. Real output depends on grain size, defect load and required carryover. Send 2–5 kg and we will return a measured figure plus a recommended configuration.